ALATAS’ SERVICEFIELD SERVICE / PARTS SUPPLY
LOCATION  EMEA / UK /  ABP SOUTHAMPTON – MARCHWOOD
EQUIPMENT  PORT CRANE
BRANDSTOTHERT AND PITT

Introduction

ABP Southampton requested ALATAS to address a breakdown under our service contract.

Background

The SLI (Safe Load Indicator) readout gradually increased from 0 to 40 tons, even with no load on the hook.

ALATAS’ Solution

Water ingress into the main control box damaged a PCB (Printed Circuit Board). We replaced the damaged PCB with a spare and calibrated the SLI using a water bag and an external load cell.

Job Scope

  • Diagnose the fault in the PCB.
  • Replace the faulty PCB with a spare unit.
  • Conduct additional fault-finding due to a faulty relay in the spare PCB.
  • Replace the faulty relay in the spare PCB.
  • Calibrate the SLI.
  • Assist the customer with spare parts and upgrade recommendations, as the current system is obsolete and the OEM no longer provides spare parts.

Scroll to Top