| ALATAS’ SERVICE | FIELD SERVICE / STRUCTURAL INSPECTION / SURVEY |
| LOCATION | EMEA / UK / SOUTH WALES |
| EQUIPMENT | LIGHTING AND OBSERVATION TOWERS / BEACON |
INTRODUCTION
Alatas UK was tasked with completing a structural assessment survey of 12 steel tower structures used for lighting and observation in the South Wales region.
BACKGROUND
The lighting, observation, and navigation towers have been subject to accidental damage and weathering conditions for many years, leading to the deterioration of paintwork and corrosion of structural members. In some cases, corrosion was accelerated by the attachment of dissimilar materials. The client sought to establish a condition baseline and develop an action plan for the steel towers, which are often overlooked.
ALATAS’ SOLUTION
The structural inspections were conducted by climbing the towers via access ladders and using a mobile elevated work platform. Alatas structural engineers performed visual inspections and provided a comprehensive closeout report with recommendations for further action. Additionally, proposals were made for further cleanup, non-destructive testing (NDT) inspection plans, and NDT inspections to initiate the repair and rectification phase.
JOB SCOPE
- Mobilize Alatas structural engineers to the site.
- Conduct visual inspections and structural surveys on 12 towers in the region.
- Demobilize and compile a closeout report, a condition matrix, and a set of recommendations for further action based on priority and urgency.
- Provide proposals for additional inspection, repair, and rectification phases.
South Wales – Light Tower Inspections/Survey gallery







An important criterion for categorisation of damage was loss of steel material greater than 10% of plate thickness






Two towers in Swansea were located at the end of marine piers.